產品明細

RT-ZH10 Passive High Voltage Probes

高電壓探棒

    產品簡述
    ♦ 頻寬: 400MHz
    ♦ 衰減係數: 100:1
    ♦ 輸入阻抗: 50 MΩ || 7.5 pF
    ♦ 動態範圍: 1000 V (RMS), 6000 V (peak)

      產品詳細介紹Product Introduction

      HIGH VOLTAGE PROBES
      The Rohde&Schwarz portfolio of high voltage probes includes passive single-ended and active differential probes for voltages up to 6000 V (peak). Different models allow measurements up to CAT IV environments. Differential probes provide an exceptional common mode rejection ratio over a broad frequency range.

      200 MHz bandwidth combined with excellent common mode rejection ratio
      In order to achieve highest power efficiencies and power densities in switched-mode power supplies, switching loss has to be minimized. This requires the use of modern, fastswitching semiconductors.
      With up to 200 MHz bandwidth and an excellent common mode rejection ratio (CMRR) over a broad frequency range, the R&S®RT-ZHD high voltage differential probes are ideal for measurements on fast-switching semiconductors. Extraordinarily low added noise results in high-quality measurements.

      Measurements with highest precision
      With 0.5% ensured gain accuracy in the signal path and a DC voltmeter (R&S®ProbeMeter) with 0.1% accuracy integrated into the probe head, the R&S®RT-ZHD probes provide the best available precision in their class. Very low drift makes regular calibration during measurements unnecessary.



      Up to 2000 V offset capability at highest vertical sensitivity
      To measure ripple voltages on the DC link, it is necessary to compensate for high offset voltages and measure with high vertical sensitivities. Due to its integrated offset circuit, the R&S®RT-ZHD probes offer an offset voltage range that is independent of the vertical setting of the oscilloscope and the attenuation factor on the probe. Now you can measure the smallest of ripple voltages on large DC link voltages without compromising sensitivity.

      Easy to use and fully integrated into the Rohde&Schwarz oscilloscopes
      An integrated, switchable, 5 MHz analog filter, an audible overrange indicator that indicates common mode voltage overrange situations, and automatic range switching make the probe easy to use. The integrated micro button allows you to control the oscilloscope from the probe.
      Fully integrated into the oscilloscope, the probe can be remote controlled for automatic testing and does not require an external power supply.

      BNC-type differential probes for less demanding applications
      For applications where bandwidth is not critical and a cost-effective solution is required, the R&S®RT-ZD01 high voltage differential probe is an excellent choice. It offers 100 MHz bandwidth for voltages up to 1400 V (peak). Due to the BNC interface, it can be connected to any oscilloscope. Power is supplied via the oscilloscope’s USB port or batteries.



      Single-ended passive probes for voltages up to 1000 V (RMS) and 6000 V (peak)
      If differential measurements are not required, single-ended passive probes are a powerful, cost-effective solution. The R&S®RT-ZH10 and R&S®RT-ZH11 passive high voltage probes provide a bandwidth up to 400 MHz and attenuation factors of 100:1 and 1000:1, respectively. Both probes are designed for RMS voltages up to 1000 V (CAT II) and – when used exclusively for pulse measurements – for peak voltages up to 6000 V (CAT I). Accessories include safety alligator clips, rigid and springloaded tips and protection caps.





      Measuring voltages up to 1000 V (RMS) with 500 MHz bandwidth
      Measuring in high voltage environments requires special safety precautions in line with the European Low Voltage Directive that depend on the actual measurement environment.
      The R&S®ScopeRider RTH lets you safely measure voltages up to 1000 V in CAT III environments or 600 V in CAT IV environments. In combination with the R&S®RT-ZI11 100:1 passive high voltage probe, a bandwidth of 500 MHz is achieved. This makes the solution interesting for measurements on GaN based power electronics components.



      ModelBandwidthAttenuation factorInput impedanceDynamic rangeComment
      Passive
      R&S®RT-ZH03 250 MHz 100:1 100 MΩ || 6.5 pF 850 V (RMS) robust 5 mm probe tip
      R&S®RT-ZH10 400 MHz 100:1 50 MΩ || 7.5 pF 1000 V (RMS), 6000 V (peak) 1000 V (RMS) CAT II, 5 mm probe tip, spring-loaded
      R&S®RT-ZH11 400 MHz 1000:1 50 MΩ || 7.5 pF 1000 V (RMS), 6000 V (peak) 1000 V (RMS) CAT II, 5 mm probe tip, spring-loaded
      R&S®RT-ZI11 500 MHz 100:1 100 MΩ || 4.6 pF 1000 V (RMS) 600 V (RMS) CAT IV, 1000 V (RMS) CAT III, 3540 V (RMS) CAT 0, for R&S®Scope Rider RTH only
      Active, differential
      R&S®RT-ZD01 100 MHz 100:1/1000:1 8 MΩ || 3.5 pF ±1400 V 1000 V (RMS) CAT III
      R&S®RT-ZHD07 200 MHz 25:1/250:1 5 MΩ || 2.5 pF ±750 V 300 V (RMS) CAT III
      R&S®RT-ZHD15 100 MHz 50:1/500:1 10 MΩ || 2 pF ±1500 V 1000 V (RMS) CAT III
      R&S®RT-ZHD16 200 MHz 50:1/500:1 10 MΩ || 2 pF ±1500 V 1000 V (RMS) CAT III
      R&S®RT-ZHD60 100 MHz 100:1/1000:1 40 MΩ || 2 pF ±6000 V 1000 V (RMS) CAT III
      Accessory
      R&S®RT-ZA24 replacement kit for R&S®RT-ZHD probes