| Outputs | The channel outputs are galvanically isolated and not connected to ground. | 
| Number of output channels | R&S®NGL201 | 1 | 
|  | R&S®NGL202 | 2 | 
| Total output power | R&S®NGL201 | max. 60 W | 
|  | R&S®NGL202 | max. 120 W | 
| Maximum output power per channel | 60 W | 
| Output voltage per channel | 0 V to 20 V | 
| Maximum output current per channel | ≤ 6 V output voltage | 6 A | 
|  | > 6 V output voltage | 3 A | 
| Maximum voltage in serial operation | R&S®NGL202 | 40 V | 
| Maximum current in parallel operation | R&S®NGL202, ≤ 6 V output voltage | 12 A | 
|  | R&S®NGL202, > 6 V output voltage | 6 A | 
| Adjustable output impedance | –50 mΩ to 100 Ω | 
| Increments |  | 1 mΩ | 
| Voltage ripple and noise | 20 Hz to 20 MHz | < 500 µV (RMS), < 2 mV (peak-to-peak) (meas.)
 | 
| Current ripple and noise | 20 Hz to 20 MHz | < 1 mA (RMS) (meas.) | 
| Electronic load | yes, R&S®NGL202: both channels | 
| Maximum sink power | R&S®NGL201 | 60 W | 
|  | R&S®NGL202 | 120 W (60 W per channel) 1) | 
| 1)  Time limited at an operating temperature of > 30°C and total power > 90 W. | 
| Maximum sink current per channel | 3 A | 
| Sink modes | constant voltage, constant current, constant resistance | 
| Load regulation | load change: 10% to 90% | 
| Voltage | ±(% of output + offset) | < 0.01% + 0.5 mV | 
| Current | ±(% of output + offset) | < 0.01% + 0.1 mA | 
| Load recovery time | regulation to within ±20 mV of the set voltage | < 30 µs (meas.) | 
| Programming resolution | 
| Voltage |  | 1 mV | 
| Current |  | 0.1 mA | 
| Programming accuracy | 
| Voltage | ±(% of the output + offset) | < 0.02% + 3 mV | 
| Current | ±(% of the output + offset) | < 0.05% + 2 mA | 
| Output measurements | 
| Measurement functions | voltage, current, power, energy | 
| Readback resolution |  | 
| Voltage |  | 10 μV | 
| Current |  | 10 μA | 
| Readback accuracy | 
| Voltage | ±(% of output + offset) | < 0.02% + 2 mV | 
| Current | ±(% of output + offset) | < 0.05% + 250 μA | 
| Temperature coefficient (per °C) | +23 °C (–3 °C/+7 °C) | 
| Voltage | ±(% of output + offset) | 0.15 × specification/°C | 
| Current | ±(% of output + offset) | 0.15 × specification/°C | 
| Sense function | yes, R&S®NGL202: both channels | 
| Maximum sense compensation | 2 V | 
| Ratings | 
| Maximum voltage to ground | 250 V DC | 
| Maximum counter voltage | voltage with the same polarity connected to the outputs | 22 V | 
| Maximum reverse voltage | voltage with opposite polarity connected to the outputs | 0.5 V | 
| Maximum reverse current | for 5 minutes max. | 1 A | 
| Remote control | 
| Command processing time | typ. < 6 ms | 
| Protection functions | 
| Overvoltage protection | adjustable, R&S®NGL202: both channels | 
| Programming resolution | 1 mV | 
| Overpower protection | adjustable, R&S®NGL202: both channels | 
| Overcurrent protection (electronic fuse) | adjustable, R&S®NGL202: both channels | 
| Programming resolution | 0.1 mA | 
| Response time | (Iload > Iresp × 2) at Iload ≥ 2 A | < 1.5 ms | 
| Fuse linking (FuseLink function) | R&S®NGL202 | yes | 
| Fuse delay at output-on | for R&S®NGL202: both channels | 0 ms to 10 s (1 ms increments) | 
| Fuse delay time | for R&S®NGL202: both channels | 0 ms to 10 s (1 ms increments) | 
| Overtemperature protection | yes | 
| Special functions | 
| Output ramp function | EasyRamp | 
| EasyRamp time | 10 ms to 10 s (10 ms increments) | 
| 10 ms to 10 s (10 ms increments) |  | 
| Synchronicity | typ. < 25 μs | 
| Delay per channel | 1 ms to 10 s (1 ms increments) | 
| Arbitrary function | QuickArb | 
| Parameters | voltage, current, time | 
| Maximum number of points | 4096 | 
| Dwell time | 1 ms to 20 h (1 ms increments) | 
| Repetition | continuous or burst mode with 1 to 65535 repetitions | 
| Trigger | manually via the keyboard, via remote control or via optional interface | 
| Trigger and control interfaces | digital I/O, R&S®NGL-K103 | 
| Display and interfaces | 
| Display | TFT 5" 800 × 480 pixels WVGA Touch | 
| Front panel connections | R&S®NGL201 | 4 mm safety sockets (channels, sense) | 
|  | R&S®NGL202 | 4 mm safety sockets (channels) | 
| Rear panel connections |  | 8-pin connector block per channel | 
| Remote control interfaces | Standard | USB-TMC, USB-CDC (virtual COM port), LAN | 
|  | R&S®NGL-K102 | WLAN | 
|  | R&S®NGL-B105 | IEEE-488 (GPIB) | 
| General data | 
| Environmental conditions | 
| Temperature | operating temperature range | +5°C to +40°C | 
|  | storage temperature range | –20°C to +70°C | 
| Humidity | Noncondensing | 5% to 95% | 
| Power rating | 
| Mains nominal voltage |  | 100 V/115 V/230 V (±10%) | 
| Mains frequency |  | 50 Hz to 60 Hz | 
| Maximum power consumption |  | 400 W | 
| Mains fuses |  | 2 × T4.0H/250 V | 
| Product conformity | 
| Electromagnetic compatibility | EU: in line with Radio Equipment Directive 2014/53/EU | applied standards: ETSI EN300 328 V2.1.1
 EN 61326-1
 EN55011 (Class A)
 EN55032 (Class A)
 ETSI EN301 489-1 V2.2.0
 ETSI EN301 489-17 V3.2.0
 | 
|  | Korea | KC mark | 
| Electrical safety | EU: in line with Low Voltage Directive 2014/35/EU | applied harmonized standards: EN 61010-1 | 
|  | USA, Canada | CSA-C22.2 No. 61010-1 | 
| WLAN approvals | Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United Kingdom | CE0682 | 
|  | Singapore | iMDA standards DB102020 | 
|  | USA, Canada | FCC, IC | 
| RoHS | in line with EU Directive 2011/65/EU | EN50581 | 
| Mechanical resistance | 
| Vibration | Sinusoidal | 5 Hz to 55 Hz, 0.3 mm (peak-to-peak) 55 Hz to 150 Hz, 0.5 g const., in line with EN 60068-2-6 | 
|  | Wideband noise | 8 Hz to 500 Hz, acceleration: 1.2 g (RMS) in line with EN 60068-2-64 | 
| Shock |  | 40 g shock spectrum, in line with MIL-STD-810E, method 516.4, procedure I | 
| Mechanical data | 
| Dimensions | W × H × D | 222 mm × 97 mm × 436 mm (8.74 in x 3.82 in x 17.17 in) | 
| Weight | R&S®NGL201 | 7.1 kg (15.6 lb) | 
|  | R&S®NGL202 | 7.3 kg (16.1 lb) | 
| Rack installation |  | R&S®HZN96 option | 
| Recommended calibration interval | operation 40 h/week over entire range of specified environmental conditions | 1 year |